• Warm Floor Heating Systems Ce and VDE Approved
  • Warm Floor Heating Systems Ce and VDE Approved
  • Warm Floor Heating Systems Ce and VDE Approved
  • Warm Floor Heating Systems Ce and VDE Approved
  • Warm Floor Heating Systems Ce and VDE Approved
  • Warm Floor Heating Systems Ce and VDE Approved

Warm Floor Heating Systems Ce and VDE Approved

Type: Insulated
Conductor Type: Alloy
Application: Heating, Underground
Conductor Material: Copper
Sheath Material: PVC
Insulation Material: XLPE
Customization:
Gold Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SHIHM-150w-230v
Material Shape
Round Wire
Range of Application
LSOH
Certification
ISO9001, CE, VDE
Brand
Senphus
Floor Heating Cable Color
White, Red, Yellow, etc. If You Need Other Color
Power
1m 10W-25W You Choose
Floor Heating Wire Cable Power
1 Square Meter 80W-200W You Choose
Cold Cable Length
2m, 3m, 4m, etc.
Electric Underfloor Heating Cable Models
3m, 5m, 7m, 9m, 15m, 20m, You Choose
Heating Cable Color
Blue, Orange, Red, Purple, Rose, etc
Transport Package
Caton-Woodcase-Pallet-Colourbox-White
Specification
0.5*2-0.5*24
Trademark
SENPHUS
Origin
China
HS Code
85168000
Production Capacity
8000 Square Meter Per Day

Product Description

Warm Floor Heating Systems CE and VDE approved
Senphus Group can produce all kinds of  warm floor heating systems with different materials and many different equipments and machines.
Custom is welcome.
At present, we only offer installation service in China.
if you have large quantities, and we can offer free installation service in abroad




Warm Floor Heating Systems Ce and VDE Approved
 
Voltage Square meters Power Ohm Length(m)
230V 1 150 352.7  11.1
230V 1.5 225 235.1  16.65
230V 2 300 176.3  22.2
230V 2.5 375 141.1  27.75
230V 3 450 117.6  33.3
230V 3.5 525 100.8  38.85
230V 4 600 88.2  44.4
230V 4.5 675 78.4  49.95
230V 5 750 70.5  55.5
230V 5.5 825 64.1  61.05
230V 6 900 58.8  66.6
230V 7 1050 50.4  77.7
230V 8 1200 44.1  88.8
230V 9 1350 39.2  99.9
230V 10 1500 35.3  111
230V 12 1800 29.4  133.2
 
Warm Floor Heating Systems Ce and VDE Approved
Warm Floor Heating Systems Ce and VDE Approved

Warm Floor Heating Systems Ce and VDE Approved

Installation advice
 
1.All electrical wiring must be done by a fully qualified electrician and in accordance with the current IEE.
 
2.The insulation Board must be installed if you have a wooden substrate.It is also commendatory with concrete substrates to optimize efficiency and reduce warming times(up to 50% more thermally efficient).
 
3.Always round down your floor space area e.g.2.6m²of floor will require 2m²of matting (To avoid surplus matting).
 
4.Never overlap the mat ,always ensure a min.50mm spacing between the wires for optimum heat distribution.
 
5.If there is a matting shortfall in your floor space then concentrate the heat mat in heavily trafficked areas.
 
6.A Residual Current Device (RCD) should be used with this system (must be bought separately).
 
7.Floor must be clean and free from dust &dirt.

 
8. Never cut the red wire or join two or more mats together in series, use a junction box.
Only use scissors when cutting the mesh.
 
9.The wire is tough but extra care must be taken when using sharp objects near the mat. A plastic trowel is advisable.
 
10.Check your system with a mufti-meter before tile installation.
 
11.Ensure your tile adhesive is suitable for use with under tile heating e.g.highly polymer modified (flexible).
 

Your substrate and floor covering,e.g.tile adhesive or screed, must be comm.\Katelyn dry before switching on your system for the first time.
Wear gloves when handing the mat (to avoid irritation to skin).
 
Take care when tiling to ensure you do not dislodge or damage the wire from the mesh mat.
 
The insulation board is not suitable for floor strengthening and structural reinforcing.
 
Matting and Insulation Board should not be passed under permanent fixings e.g.bath,toilet etc.
 
Do not store objects on top of the matting during installation e.g.tiles.
Remove old floor coverings
 


Warm Floor Heating Systems Ce and VDE Approved
Warm Floor Heating Systems Ce and VDE Approved


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now