electric underfloor heating mats
1.cost effective
2.CE, UL,SAA
3.easy instalation
4.factory
---------------------------------------------------------------------------------------------------------------------------------------------
electric underfloor heating mats :
Electric underfloor heating mat combines the highest comfort level with maximum energy efficiency. It's a proven technology that's safe, reliable and energy efficient(saving 30%-40% compared with traditional electric underfloor heating mat ).
1. Twin core heating cable with black cold lead
2. Size is available from 1 to 12 sqm coverage
3. Teflon/PVC/FEP insulation for long service life
4. Tinned copper earth braid
Each electric underfloor heating mat include:
1. Underfloor heating cable mat stitched on self-adhesive mesh
2. Digital, fully programmable thermostat with built in timer
3. Floor sensor
Safe:High efficient and convient electric underfloor heating mat .
Automatism: CE UL electric underfloor heating mat can automatically(by thermostat) measure the heating requirement, and timely adjust the temperature.
Economical: The cost of installation and operation is relatively low; our electric underfloor heating mat can efficiently avoid damage and save maintain fees.
Eco-friendly: Our electric underfloor heating mat use the cleanest and most efficient power which are popular between customers.
Warranty: 10 years
Benefits of electric underfloor heating mat :
There are no radiators to spoil the clean lines of a room, and space can be saved by freeing up a wall that would otherwise need to be dedicated to a radiator.
Electric underfloor heating mat is also an extremely efficient way to warm a room, and gives a more pleasant heat than radiators, stoves or traditional solid-fuel fires. Heat is emited in a very gentle way. There are no cold spots and, as most of the heat is concentrated in the lower part of the room, very little heat is wasted.
Electric underfloor heating mat which is attached to open-weave mesh mats. There are, however, newer types where the elements are embedded into a continuous roll. The mats or rolls are spread out on the floor, connected together and are then linked up to the thermostat and mains power supply.
In general, whilst electric underfloor heating mat is cheaper to install, and cause less disruption to existing floor structure, they are cheaper to run than wet systems, which are more cost efficient.
--------------------------------------------------------------------------------------------------------------------------------------------
Electric underfloor heating mat Specification:
Type |
voltage |
Rated power |
Resistance @20oC+10/-5% |
Mat size |
Length |
V |
W |
Ω |
m |
m |
SHHM-160-0.5M2 |
220 |
80 |
605 |
0.5X1.0 |
5.55 |
SHHM-160-1.0M2 |
220 |
160 |
302.5 |
0.5X2.0 |
11.1 |
SHHM-160-1.5M2 |
220 |
240 |
201.7 |
0.5X3.0 |
16.65 |
SHHM-160-2.0M2 |
220 |
320 |
151.3 |
0.5X4.0 |
22.2 |
SHHM-160-2.5M2 |
220 |
400 |
121.0 |
0.5X5.0 |
27.75 |
SHHM-160-3.0M2 |
220 |
480 |
100.8 |
0.5X6.0 |
33.3 |
SHHM-160-3.5M2 |
220 |
560 |
86.4 |
0.5X7.0 |
38.85 |
SHHM-160-4.0M2 |
220 |
640 |
75.6 |
0.5X8.0 |
44.4 |
SHHM-160-4.5M2 |
220 |
720 |
67.2 |
0.5X9.0 |
49.95 |
SHHM-160-5.0M2 |
220 |
800 |
60.5 |
0.5X10.0 |
55.5 |
SHHM-160-6.0M2 |
220 |
960 |
50.4 |
0.5X12.0 |
66.6 |
SHHM-160-7.0M2 |
220 |
1120 |
43.2 |
0.5X14.0 |
77.7 |
SHHM-160-8.0M2 |
220 |
1280 |
37.8 |
0.5X16.0 |
88.8 |
SHHM-160-9.0M2 |
220 |
1440 |
33.6 |
0.5X18.0 |
99.9 |
SHHM-160-10M2 |
220 |
1600 |
30.3 |
0.5X20.0 |
111 |
SHHM-160-12M2 |
220 |
1920 |
25.2 |
0.5X24.0 |
133.2 |
|
|
|
|
|
|
Remarks: It can be changed according to customers' requirements.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
electric underfloor heating mat Installation
1) Don't damage heat mat.
2) Well installation can guarantee the efficiency.
3) After the installation, take a full test and make sure the system works well.
4) Heat insulation materials should be dry and the joint of cable should be sealed.
5)The junction box should be sealed to prevent water leak.
6) Protective sleeve must not be damaged during installation, and the core wire can not bare.