Outdoor Snow Melting Cable Twin Conductor Two Heating Wires

Product Details
Customization: Available
Type: Insulated
Conductor Type: Stranded
Still deciding? Get samples of US$ 1/Meter
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
515
Year of Establishment
2002-11-07
  • Outdoor Snow Melting Cable Twin Conductor Two Heating Wires
  • Outdoor Snow Melting Cable Twin Conductor Two Heating Wires
  • Outdoor Snow Melting Cable Twin Conductor Two Heating Wires
Find Similar Products

Basic Info.

Application
Heating
Conductor Material
Colomony Thread
Sheath Material
PVC
Insulation Material
Aluminum Foil
Material Shape
Round Wire
Range of Application
Cold-Resistant
Certification
ISO9001, CE
Power
40W/M
Voltage
220V 380V
Transport Package
Carton
Specification
Colomony thread Flame retardant PVC outeiacket
Trademark
SENPHUS
Origin
China

Product Description

Application

Outdoor snow melting

Outdoor Snow Melting Cable Twin Conductor Two Heating Wires


Radial power supply is adopted, which is led out from the snowmelt heating cable distribution box and laid along the cable bridge inside the outer wall of the lane to each heating cable.
The control mode is automatic and manual. In the automatic mode, PLC is used as the main control unit. The intelligent temperature inspection instrument transmits the surface temperature of the lane to the PLC. At the same time, the snowfall and rainfall detector transmits the snowfall or rainfall information to PLC. PLC compares the above information with the set temperature, and puts in or cuts off the number and time of heating cable according to the set program.The heating cable can also be manually put in and cut off. The intelligent temperature inspection instrument is installed on the distribution box to display the temperature of each temperature measuring point in real time. When the temperature exceeds the limit, the sound and light alarm will be given and the operation of the heating cable will be stopped.


Grounding


The grounding wire, metal protective layer, threading steel pipe, cable bridge and metal shell of distribution box of all heating cables shall be reliably grounded (PE).

Type/Power
Type Cable length Power(W) Voltage(V) Resistance(Ω)
SHSM-40-40M-220V 40 1600 220 30.25
SHSM-40-60M-220V 60 2400 220 20.17
SHSM-40-80M-220V 80 3200 220 15.13
SHSM-40-100M-220V 100 4000 220 12.10
SHSM-40-120M-220V 120 4800 220 10.08
SHSM-40-40M-380V 40 1600 380 90.25
SHSM-40-60M-380V 60 2400 380 60.17
SHSM-40-80M-380V 80 3200 380 45.13
SHSM-40-100M-380V 100 4000 380 36.10
SHSM-40-120M-380V 120 4800 380 30.08
Outdoor Snow Melting Cable Twin Conductor Two Heating Wires
Outdoor Snow Melting Cable Twin Conductor Two Heating Wires

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier