Cu- CuNi (Constantan) thermocouple wire (Type T)
Cu-CuNi thermocouple (type T) is also named Cu- Constantan thermocouple. The positive leg Cu(TP) is made by pure Copper, and the main chemical composition of negative leg Constantan (TN) is Cu: Ni≈ 55%: 45%. Although EN, TN, JN are all called Constantan, TN and EN don not give the same EMF output curve as JN. EN and TN are able to interchange but they are not interchangeable with JN. The operating temperature range of type T thermocouple is -200~350ºC , Due to the low resistance of oxidation that Copper has, it is not advisable to go beyond that range.
Type T thermocouple has good resistance to oxidation, high EMF output, with good temperature accuracy, sensitivity and stability. In the temperature range -200~0 ºC , it has better property, the year stability is less than ±3μV .
Thermocouple temperature range and tolerance
Name |
Grade |
operating temperature range(ºC) |
temperature range(ºC) |
Tolerance |
standard |
long term |
short term |
K |
l |
1200 |
1300 |
-40~1100 |
+1.5ºC or+0.4%t |
GB/T2614 |
ll |
-40~1300 |
+2.5ºC or+0.75%t |
E |
l |
750 |
900 |
-40~800 |
+1.5ºC or+0.4%t |
GB/T4993 |
ll |
-40~900 |
+2.5ºC or+0.75%t |
J |
l |
600 |
750 |
-40~750 |
+1.5ºC or+0.4%t |
GB/T4994 |
ll |
-40~350 |
+2.5ºC or+0.75%t |
T |
l |
300 |
350 |
-40~350 |
±0.5ºC or±0.4%t |
GB/T2903 |
ll |
±1ºC or±0.75%t |
lll |
-200~40 |
±1ºC or±1.5%t |
N |
l |
1200 |
1300 |
-40~1100 |
+1.5ºC or+0.4%t |
GB/T17615 |
ll |
-40~1300 |
+2.5ºC or+0.75%t
|